HOME > FAQ

QA1

  • What is the difference between RSH and AHS models?

    The RSH hybrid inverter is our innovative machine which can be used in three mode: 1. Grid tie inverter 2. Off grid system  3. Grid tie inverter with backup power system. 
     
    The AHS is our off grid product which consist of pure sine wave inverter plus ac and solar charger.  It can be DC or AC priority setting.  DC priority mode means that the load consumes the DC power from the battery which in turn is powered by the PV first, once the voltage of the battery is too low, it will auto switch to the grid so that the grid can charge the battery and the load; whereas the AC priority mode means the load consumes the power from the AC grid first, once there is outage, it will auto switch to battery for power support. 
     

  • What is the features of the RSO three phases output stackable charger inverter?

     

    Our RSO is the state-of-the-art product so far, it can be three phases output and stackable to max. 90Kw based on our largest model of 6Kw.  The sum up, its features are:
     
    1. Combi-functions, has intelligent shore and generator power management
    2. Uninterrupted AC power (UPS function)
    3. Virtually unlimited power thanks to parallel operation
    4. Three phase capability
    5. PowerControl – Dealing with limited generator, shore side or grid power to
      avoid sudden loads on generator causing voltage spikes
    6. PowerSupport – Boosting the capacity of shore or generator power, innovative
     feature of the RSO series.
    7. Communication with max. 10 sets of solar chargers-RSS series.
    8. Four preset control mode application with AC grid, AC charging and solar
     charging
    9. Mode 1 takes the AC mains input power to supply to the load or charge the
     batteries
    10. Mode 2 incorporates the “maximum AC input current limit” to protect against
        unwanted power tripping from the mains supply of the backup generator
    11. Mode 3 and Mode 4 are “Green Power Smart Feature” and designed to
       conserve energy by using the solar power to recharge the batteries.
       The difference between mode 3 and mode 4 is that the AC charger in the RSO
      series is always off in mode 3
    12. Wall Mount and Table Mount available for choices
    13. Optional remote panel with LCD display for easy operation in distance
     

     

     

     

     

     

  • Highest Power Density Online UPS with Superb Runtime for Your PCs

    Highest Power Density Online UPS with Superb Runtime for Your PCsHighest Power Density Online UPS with
    SDensity Online UPS with Superb Runtime for Your PCsHighest Power Density Online UPS with Superb
    Runtime for Your PCs